Uterine Tachysystole with Prolonged Deceleration Following Nipple Stimulation for Labor Augmentation

Authors

  • D.M. Narasimhulu Department of Obstetrics and Gynecology Maimonides Medical Center 4802, 10th ave, Brooklyn, New York
  • L. Zhu Department of Obstetrics and Gynecology Maimonides Medical Center 4802, 10th ave, Brooklyn, New York

DOI:

https://doi.org/10.3126/kumj.v13i3.16820

Keywords:

Deceleration, labor, nipple stimulation, uterine tachysystole

Abstract

Breast stimulation for inducing uterine contractions has been reported in the medical literature since the 18th century. The American college of Obstetricians and Gynecologists (ACOG) has described nipple stimulation as a natural and inexpensive nonmedical method for inducing labor.

We report on a 37 year old P2 with a singleton pregnancy at 40 weeks gestation who developed tachysystole with a prolonged deceleration after nipple stimulation for augmentation of labor. Initial resuscitative measures, including oxygen by mask, a bolus of intravenous fluids and left lateral positioning, did not restore the fetal heart rate to normal. After the administration of Terbutaline 250 mcg subcutaneously, the tachysystole resolved and the fetal heart rate recovered after five minutes of bradycardia.

Most trials of nipple stimulation for induction or augmentation of labor have had small study populations, and no conclusions could be drawn about the safety of nipple stimulation, though its use is widespread. While there have been a few reports of similar complications during nipple stimulation for contraction stress testing, there are no previous reports of tachysystole with sustained bradycardia following nipple stimulation for labor augmentation.

In this report, we draw attention to the dangers of nipple stimulation so that providers will be aware of this potential complication.

Downloads

Download data is not yet available.
Abstract
804
PDF
955

Downloads

Published

2017-02-26

How to Cite

Narasimhulu, D., & Zhu, L. (2017). Uterine Tachysystole with Prolonged Deceleration Following Nipple Stimulation for Labor Augmentation. Kathmandu University Medical Journal, 13(3), 268–270. https://doi.org/10.3126/kumj.v13i3.16820

Issue

Section

Case Reports